When purchasing textile and dyeing machinery for the EU, what are the key CE compliance points under Machinery Directive and Low Voltage Directive?
• Machinery Directive 2006/42/EC requires risk assessment, guards and E-stop per EN ISO 13849.
• Low Voltage Directive 2014/35/EU covers electrical cabinets: insulation ≥1500V, grounding ≤0.1Ω.
• Provide CE Declaration of Conformity, technical file and EN ISO 12100 risk assessment.
• Dyeing machines with steam need CE marking plus PED assessment for pressure equipment.
• Low Voltage Directive 2014/35/EU covers electrical cabinets: insulation ≥1500V, grounding ≤0.1Ω.
• Provide CE Declaration of Conformity, technical file and EN ISO 12100 risk assessment.
• Dyeing machines with steam need CE marking plus PED assessment for pressure equipment.