How should the electrostatic module of an integrated unit be cleaned?
Switch off the power, remove the cell according to the manual, soak it with a suitable degreaser, clean it with a soft brush, dry it thoroughly, and then check discharge and insulation after reinstallation.
Do not scrape the plates with abrasive pads or disassemble the unit while powered.
Checklist:
Define capacity, accuracy, materials and operating environment before requesting quotes on a uniform basis.
Request specification sheets, test reports, certificates, maintenance manuals and spare-part lists.
During acceptance, verify appearance, dimensions, functions, safety protection and packaging, and keep test records.
Do not compare unit price alone; include customization, freight, spare parts, after-sales support and downtime risk.
Keep written records of inquiries, confirmations, FAT, acceptance and warranty commitments.