How should the cells of an electrostatic purifier be washed?
Switch off the power, remove the cells, soak them with a suitable degreaser, clean with a soft brush, rinse and dry thoroughly, then check insulators, plate spacing and grounding.
Do not let water enter the power supply or deform the plates during handling.
Checklist:
Define capacity, accuracy, materials and operating environment before requesting quotes on a uniform basis.
Request specification sheets, test reports, certificates, maintenance manuals and spare-part lists.
During acceptance, verify appearance, dimensions, functions, safety protection and packaging, and keep test records.
Do not compare unit price alone; include customization, freight, spare parts, after-sales support and downtime risk.
Keep written records of inquiries, confirmations, FAT, acceptance and warranty commitments.